Why Does My Heat Pump Use Emergency Heat in Winter?

Seeing the red “EM HEAT” light on your thermostat in the middle of winter can be alarming, especially when you know your electric bill is about to climb. A heat pump may switch to emergency or auxiliary heat when outdoor temperatures drop, when it needs to defrost, or when a part fails. Some of these cases are normal, while others signal a repair.

This guide explains what emergency heat is, why it turns on, how much it costs, and what you can do to keep your heat pump running efficiently all winter.

What Is Emergency Heat on a Heat Pump?

Emergency heat is a backup heating mode that uses electric resistance coils instead of the heat pump’s compressor. It is designed for situations where the outdoor unit cannot do its job.

Two terms are often confused, so here is the difference:

  • Auxiliary heat (aux heat): Electric heat strips that switch on automatically to help the heat pump when it cannot keep up. The compressor keeps running, and the strips add extra warmth.
  • Emergency heat (EM heat): A manual setting on the thermostat. It shuts the compressor out completely and uses only the backup heat source, such as electric strips or, in a dual fuel system, a gas furnace.

On many thermostats, an “AUX” light means the strips are helping, while an “EM HEAT” light means you selected emergency mode, or a thermostat fault selected it for you.

A heat pump does not create heat by burning fuel. It moves heat from outdoor air into your home using refrigerant, a compressor, and a reversing valve. That process is very efficient, but it gets harder as outdoor air gets colder. Electric strips fill the gap, and knowing how they work makes it easier to see why they turn on, which we cover next.

Why Does a Heat Pump Switch to Backup Heat in Cold Weather?

The most common reason is simple: when it gets cold enough, the heat pump alone cannot meet your home’s heating demand.

The balance point: Every heat pump has a balance point, the outdoor temperature at which its heating output equals your home’s heat loss. Below that temperature, the heat pump falls short, and aux heat covers the difference. For many standard systems, the balance point falls somewhere in the 30°F to 35°F range, though it varies with equipment, insulation, and climate.

Cold climate models: Newer cold climate heat pumps use variable speed compressors and enhanced refrigerant cycles. Many are rated to deliver useful heat at 5°F or below, so they rely on backup heat much less than older units.

Big thermostat jumps: Raising the setpoint by several degrees at once tells the system you need heat fast. The thermostat may call for aux heat to speed up recovery, even if the heat pump could reach the temperature gradually.

Large overnight setbacks: Dropping the temperature at night and raising it in the morning often triggers strips, because the heat pump cannot make up a big gap quickly.

Thermostat settings: Some thermostats let installers set an outdoor temperature lockout for the strips. If it is set too high, the strips may run even in mild weather.

Cold weather is not the only trigger, though. A routine maintenance cycle can also bring on backup heat, as we explain next.

Is the Defrost Cycle Making My Backup Heat Come On?

Yes, and it is completely normal. During cold, damp weather, frost builds up on the outdoor coil, which reduces airflow and efficiency.

To clear it, the heat pump briefly reverses into cooling mode and sends warm refrigerant to the outdoor coil. That process draws heat from the indoor air, so the system turns on the electric strips to keep the air from the vents from feeling cool.

What to expect during a normal defrost cycle:

  • The outdoor unit may release a cloud of steam or water vapor.
  • The outdoor fan usually stops for a few minutes.
  • Defrost typically lasts about 5 to 10 minutes, though the exact time varies by model.
  • Cycles repeat as needed, often every 30 to 90 minutes in freezing, humid weather.
  • The indoor air may feel slightly cooler for a moment, and aux heat may light up.

Defrost becomes a concern when the outdoor unit is covered in thick ice, the cycle never ends, or the unit freezes into a solid block. Those signs point to a problem with the defrost control, sensor, reversing valve, or refrigerant charge.

Normal defrost is easy to spot. A true mechanical fault is a different story, so let’s look at those next.

Equipment Problems That Force Emergency Heat

If your system is stuck in EM heat or relies heavily on the strips in mild weather, something may be wrong with the heat pump.

Common causes include:

  1. Compressor failure: The compressor is the heart of the system. If it fails, the thermostat or the homeowner has to switch to backup heat.
  2. Low refrigerant: A leak reduces heating capacity, so the strips run more often.
  3. Faulty reversing valve: A stuck valve can leave the system in the wrong mode or unable to defrost.
  4. Failed capacitor or contactor: These electrical parts start the compressor and fan. When they fail, the outdoor unit may not run at all.
  5. Outdoor fan motor problems: Without airflow across the coil, the unit cannot absorb heat.
  6. Iced or dirty outdoor coil: Snow, ice, leaves, and debris block airflow.
  7. Dirty indoor filter or coil: Restricted airflow lowers performance and can freeze the indoor coil.
  8. Thermostat or wiring faults: Incorrect settings or a wiring issue can place the system in emergency mode when it is not needed.
  9. Tripped breaker: The outdoor unit and the backup heat strips often share power circuits, so a tripped breaker can change how the system behaves.

If you suspect a mechanical failure, avoid repeated resets, and call a licensed HVAC technician. Running a damaged compressor can make repairs more expensive.

How Much Does Emergency Heat Cost to Run?

Emergency heat is much more expensive than normal heat pump operation because electric resistance heating gives you only as much heat as the energy it uses.

Efficiency is measured by the coefficient of performance (COP). Resistance heat has a COP of 1.0, meaning 1 unit of electricity makes 1 unit of heat. Heat pumps can deliver a COP of 2 to 4 depending on outdoor temperature and equipment, since they move heat instead of creating it.

The table below shows an example cost to deliver 10,000 BTU of heat. It assumes electricity at $0.15 per kWh, and one kWh equals about 3,412 BTU. The numbers come from basic math, not from a specific home.

Heating Method Approximate COP Cost per 10,000 BTU
Electric resistance (emergency heat) 1.0 $0.44
Heat pump in very cold weather 2.0 $0.22
Heat pump in moderate cold 3.0 $0.15
Heat pump in mild weather 4.0 $0.11

In this example, running on emergency heat can cost two to four times as much as running the heat pump itself. A few days of continuous strip heat can produce a noticeably higher monthly bill. If you use a dual fuel system with a gas furnace as the backup, the cost depends on local gas and electricity prices.

Because backup heat is so expensive, it is worth knowing when to use it on purpose and when to leave it alone.

When Should You Use Emergency Heat?

For most households, the answer is rarely, and only when the outdoor unit is not working.

Use EM heat when:

  • The outdoor unit has failed or stopped running.
  • The unit is encased in ice and not defrosting.
  • You hear loud grinding, screeching, or banging from the outdoor unit.
  • You are waiting for a technician and need to keep the house warm.

Do not use EM heat when:

  • It is merely cold, since the system will use aux heat automatically.
  • You want a faster warm-up. The strips will still run on their own if needed.
  • The heat pump is working normally but running longer than usual.

Switching to EM heat lets you stay warm while avoiding more damage to a failed compressor. Once the repair is complete, set the thermostat back to normal heating mode so the heat pump can return to its efficient operation.

If you are not sure which mode your system is in, check the thermostat display or the manual, and ask your installer to explain the controls.

How to Reduce Backup Heat Use This Winter

Small changes can keep your heat pump working at its most efficient and keep the strips off more often.

  1. Raise the temperature gradually: Increase the setpoint by 1 to 2 degrees at a time instead of making big jumps.
  2. Use smaller setbacks: Keep night setbacks to about 2 to 3 degrees, or use a thermostat designed for heat pumps with smart recovery.
  3. Replace filters regularly: Check monthly and replace them every 1 to 3 months.
  4. Keep the outdoor unit clear: Remove snow, ice, leaves, and debris, and keep at least 2 feet of space around the unit. Use warm water, not tools, to clear ice.
  5. Schedule annual service: Ask the technician to check refrigerant charge, electrical parts, defrost controls, and the reversing valve before winter.
  6. Seal and insulate: Reducing air leaks and adding attic insulation lowers the heating load, which keeps the balance point lower.
  7. Check duct leakage: Leaky ducts reduce delivered heat and increase backup use.
  8. Review thermostat settings: Ask a technician to confirm the outdoor lockout temperature for the strips.
  9. Consider an upgrade: If your equipment is old or undersized, a cold climate model with a variable speed compressor can cut backup heat use sharply.

Many utilities and government programs offer rebates for efficient heat pumps, so it is worth checking incentives in your area before replacing equipment.

Final Thought

A heat pump using backup heat in winter is often normal, whether because of low outdoor temperatures, defrost cycles, or a fast thermostat change. The real concern is when the EM heat light stays on for days, the outdoor unit is not running, or your bills spike without explanation. Keep filters clean, keep the outdoor unit clear, make small thermostat adjustments, and book a yearly tune-up. If the system seems stuck in backup mode, call a licensed HVAC technician for a diagnosis.

FAQs

Is It Normal For My Heat Pump To Use Auxiliary Heat In Winter? 

Yes. Aux heat is designed to switch on when outdoor temperatures fall below the balance point, during defrost cycles, or when the system needs to recover from a large temperature change. Occasional use is normal. Constant use in mild weather is not.

What Is The Difference Between Emergency Heat And Auxiliary Heat? 

Auxiliary heat works alongside the compressor and turns on automatically. Emergency heat is manually selected and shuts the compressor out, using only the backup source. Emergency heat should be reserved for outdoor unit failures.

Why Did My Thermostat Switch To EM Heat By Itself? 

Some thermostats activate EM mode when they detect a fault, a communication problem, or a wiring issue with the outdoor unit. A tripped breaker or a failed component can also cause it. Check the breaker and call a technician if the mode keeps returning.

At What Temperature Does A Heat Pump Stop Working? 

There is no single cutoff. Standard models lose capacity quickly as it gets colder, and many rely on strips below the low 30s. Cold climate models are built to deliver useful heat at 5°F and below, with some rated to even lower temperatures.

Will Running Emergency Heat Damage My Heat Pump? 

Running EM heat does not harm the system itself, and it can actually protect a failed outdoor unit from further damage. The main downside is cost. Leaving it on for long periods can increase your electric bill significantly.

How Do I Know If My Heat Pump Is In Defrost Mode? 

You may see steam rising from the outdoor unit, hear a whooshing sound as the reversing valve shifts, and notice the outdoor fan stopping. The thermostat may show aux heat. A normal cycle lasts roughly 5 to 10 minutes.

Why Is My Electric Bill So High With A Heat Pump In Winter?

High bills often come from frequent strip heat use, long stretches of extreme cold, large thermostat setbacks, a dirty filter, or a refrigerant problem. Compare your bills to the weather, and ask a technician to inspect the system if usage seems out of line.

Should I Turn Off The Aux Heat To Save Money? 

Usually no. Turning it off completely can leave your home cold and may slow recovery. A better approach is to use smaller thermostat adjustments, improve insulation, and have a technician check the aux lockout temperature.

Can Ice On My Outdoor Unit Be A Sign Of A Problem? 

A thin layer of frost is normal and is cleared during defrost. A thick coating of ice, a unit that is frozen solid, or a cycle that never ends points to a defrost control failure, low refrigerant, an airflow issue, or a stuck reversing valve.

Is A Dual Fuel System Better Than Electric Backup Heat? 

It can be, depending on local energy prices. A dual fuel setup pairs a heat pump with a gas furnace, which takes over when it gets too cold. In areas with cheap natural gas and very cold winters, it can cost less to run than electric strips.

 